Hi Rob,

On Sun, Dec 19, 2021 at 11:34 AM Rob Landley <rob****@landl*****> wrote:
> On 12/16/21 8:17 AM, Geert Uytterhoeven wrote:
> >       Hi Greg, Jiri,
> >
> > This patch series contains a legacy cleanup and two small improvements
> > for the Renesas (H)SCI(F) serial driver.
>
> Tested-by: Rob Landley <rob****@landl*****>

Thanks!

> By the way, did you ever figure out how to get the first serial port to work on
> qemu so qemu-system-sh4 doesn't have to "-serial null -serial mon:stdio" to get
> a serial console?

Nope, same as last time you asked ;-)

However, upon a fresh look at linux/arch/sh/boards/mach-r2d/setup.c,
I noticed something I missed before: the SCI port is not available
as a UART, as it is used to talk SPI to an RTC.  So that means qemu
has the hardware description wrong?

Gr{oetje,eeting}s,

                        Geert

--